Industry
Production and technology zones
Conventional Controller-Based Access Control System | Seenaptec Access Platform |
|---|---|
Access is assigned to passage points and modes associated with the facility structure in the access control system. | Access is assigned to logical objects, tags, and routes, regardless of the installed device model. |
A new zone requires configuring its entry and exit points and their modes. | A zone is created as a perimeter; objects are designated as entrances and exits, after which the system tracks occupancy. |
Anti-passback is configured through zone control and passage modes. | The perimeter supports hard anti-passback with access denial and a soft mode that records violations. |
Moving a point to another controller requires changing the hardware configuration. | The object is retained; the bindings of its functional slots are changed. |
Access to technological equipment
Typical controller-based ACS | Seenaptec Access Platform |
|---|---|
Access to equipment is implemented through an access point and special mode rules. | Equipment or an automation cabinet is described by an object with its own rules. |
Qualification verification usually requires an additional personnel parameter or integration. | Access may depend on the presence of a condition: permit, briefing, medical examination, or work permit. |
Limiting the number of operations is configured by a special mode or external logic. | A pass may have an entry limit; write-off is performed by the object rule. |
Separate sets of points and modes are formed for different workshops. | Objects are grouped by tags and included in maintenance routes. |
Contract work and support
Typical controller-based access control system | Seenaptec Access Platform |
|---|---|
Temporary pass and approval route are handled by a separate functional section. | The request is a draft of the pass and does not grant access until issuance. |
Special escort mode is configured in the access mode. | Escort is set by the identification mode of the protected object. |
For each point, it is necessary to ensure the applicability of the required mode. | One object rule applies to all passes requesting access to it. |
Work completion monitoring is based on the passage log. | Current access shows presence in perimeters and active sessions. |
Commissioning and maintenance
Typical Controller-Based Access Control System | Seenaptec Access Platform |
|---|---|
The engineer works with the controller configuration, its inputs, outputs, and onboard memory. | The engineer sees the device as a set of components assigned to slots of the protected facility. |
Signal verification is performed based on the controller status and access point events. | LIVE mode shows the path of each signal from the device to the server. |
A standard configuration is transferred between controllers or access points. | Configuration and assignment templates are applied in bulk by manufacturer and model. |
Updating depends on compatibility between the software version and the controller firmware. | The firmware catalog is used to automatically select the file and verify the version after installation. |